Postersland

Confidence is Not Reliability: Rethinking MC Dropout in Brain Tumour Segmentation

2026-06-17 · arXiv: 2606.19300

One-line summary

A robotics research paper on Confidence is Not Reliability: Rethinking MC Dropout in Brain Tumour Segmentation.

Engineering notes

Engineering notes will be added by the Robot Papers editorial team.

Chinese explanation / 中文解读

中文解读待补充:本站会优先为 VLA、具身智能、人形机器人控制、机器人操作等高价值论文补充中文说明。

Original abstract

Glioma segmentation in multiparametric MRI is a critical component of treatment planning. A segmentation model that fails silently on treatment-critical sub-regions represents a patient safety risk that overlap-based metrics such as Dice scores cannot expose. We ask whether voxel-level uncertainty estimation via Monte Carlo (MC) Dropout can reliably identify segmentation errors in clinically critical sub-regions, and whether calibration failure modes are detectable from standard reporting metrics alone. In an empirical two-model case study on 126 BraTS21 patients, we evaluate a high-performance pretrained SegResNet and a locally trained UNet with residual units (UNet-Res). MC dropout preserved segmentation accuracy ($|Δ\text{Dice}|$ $<0.01$) while achieving strong uncertainty-error alignment (AUROC for entropy (H) $\approx$0.97), indicating uncertainty correctly ranks erroneous voxels above correct ones. Entropy-based patient stratification identified a high-uncertainty subgroup with substantially lower segmentation performance (median whole-tumour Dice $0.835$ vs. $0.925$), supporting uncertainty as a practical triage signal. However, global alignment can mask important region-specific differences. Despite similar AUROC, UNet-Res exhibited near-zero enhancing tumour entropy ($0.054$) and Expected Calibration Error (ECE) of $0.915$, with a Dice of only $0.714$, indicating severely miscalibrated confidence on the most clinically critical sub-region, a failure mode invisible to standard Dice and AUROC reporting. These findings demonstrate that strong uncertainty-error alignment is necessary but insufficient for clinical safety: sub-region-specific calibration assessment must accompany AUROC evaluation when selecting models for clinical deployment.

5.0Engineering value
7.0Research novelty
4.0Business relevance

Links and sources

Looking for custom poster printing?

Postersland offers custom poster printing, bulk orders and personalized art prints for home, office, events and gifts.

View custom printing services

Comments

No comments yet. Be the first to share your thoughts on this paper.
Login or register to leave a comment